Mode of Packing |
: |
0.375 l, 0.750 l , 2.500 l , 7.500 l and 15 l. |
|
|
|
|
Definition |
: |
It is an alkyd based, anticorrosive synthetic metal primer. |
|
|
|
Color |
: |
White, grey, red and green. |
|
|
|
Uses of... |
: |
It can be used as a primer, on iron and steel construction surfaces. It protects metal surfaces against rust. |
|
|
|
| |
Specifications |
: |
It protects metal surfaces against rust. Due to it resists to all air condition, it can be used on surface of ship which is not contact with water. It forms strong surface for topcoat paints. |
|
|
|
|
Technical Features |
: |
Type of Resin : Alkyd resin Viscosity (KU)(25°C) : 98 ± 2 Specific Gravity (g/ml) (20°C) : 1.48 ± 0.050 Solid Content (by weight) (%) : 78 ± 2 Glossy (60° - Gloss) : Matt Flash Point ( °C ) : 38 Theoretical Coverage : 16 m ² / lt ( 30 µ dry film thickness) Practical Coverage : 0,070 - 0,085 lt/m² ( one coat ) 0,100 0,125 kg/m² ( one coat ) Recommended number of coats : Two coats. Drying Time (20°C) : ust free : 3 - 5 hours Dry through : 10 -12 hours. Thin Down Ratio : 10 - 15 % (with Merbolin Synthetic Thinner.)
|
|
|
|
Application 1 |
: |
All application surface must be sound, clean and dry, Old and blistered paint coats should be cleaned and surface is sandpapered. |
|
|
|
Application 2 |
: |
Merbolin Antirust is thinned with 10-15 % Merbolin Synthetic Thinner. Merbolin Antirust should be applied with brush, roller or paint gun as one or two coats, allowing 2 - 3 hours between the coats. |
|
|
|
Storage Conditions |
: |
It should be storaged in original and closed containers at 5 - 35 ° C temperatures for three years. It should be protected from extreme heat and moisture. |
|
|
|
Önemli Uyarılar |
: |
The antirust must be mixed before the use. The ambient temperature should be between 5 � 35 ° C at the time of application Application tools must be cleaned with Merbolin Synthetic Thinner, after the application,. After the application, the coated surface must be protected during 12 hours, from chemical and physical factors. The antirust doesn�t empty into drains. Application procedures defined above should be strictly observed. |
|
|
|
Danger Warning |
: |
R 10 : Flammable. : R 20/21/22 : Harmful by inhalation, in contact with skin and if swallowed. :
|
|
|
|
Emergency Warning |
: |
S 2 : Keep out of the reach of children. : S 3 / 7 : Keep container tightly closed in a cool place. : S 24 / 25 : Avoid contact with skin and eyes. : S 29 : Do not empty into drains. : S 46 : If swallowed, seek medical advice immediately and show container or label. : S 16 : Keep away from sources of ignition, no smoking. : S 51 : Use only in well ventilated areas. :
|
|