Specifications |
: |
It is applied on concrete surface under the solventfree epoxy self levelling coating. The surface is saturated by this product which obtains strongly to adhesion between coating and surface. |
|
|
|
|
Technical Features |
: |
Type of Resin : Epoxy Resin / Polyamide Hardener Specific Gravity (g/ml) (20°C) : 1.10 ± 0.10 Glossy : Gloss Solid Content (by weight) (%) : 99 ± 1 Solid Content (by volume) (%) : 98 ± 1 Flash Point ( °C ) : Nonflammable Heat Resistance (Dry) ( °C ) : 140 Theoretical Coverage : 5 m²/l; 4 m²/kg ( 200 µ dry film thickness) Practical Coverage : 3-4 m²/kg ( 150-250 µ dry film thickness) Mixing Ratio (by weight) : I. Component : 62.5 / II. Component (Hardener): 17.5 Pot Life (20°C) : 30 - 40 minutes. Drying Time (20°C- Relative Humidity 65%) : First drying : 1 - 2 hour Drying : 5 - 6 hours Second coat application : 12 hours Full hardening : 7 days Thin Down Ratio : Thinner addition is not recommended.
|
|
|
|
Application 1 |
: |
All application concrete surface must be sound, clean, dry and free from oil. If oil on the surface, which should be cleaned by chemical cleaning materials. If oil absorbed by the surface, which is cleaned by burninng and if oil inside the concrete which is breaked and repaired. |
|
|
|
Application 2 |
: |
Solventfree Epoxy Sealer and hardener components should be mixed well observe to mixing ratio. 0.250 kg of the mixture of solventfree epoxy sealer should be applied on 1m² surface. Merepoks Solventfree Epoxy Sealer is applied 200µ dry film thickness on the clean surface with by brush or roller. Second coat application is recommended on porous surface. |
|
|
|
Storage Conditions |
: |
It should be storaged in original and closed containers at 5 - 35 ° C temperatures for one year. It should be protected from extreme heat and moisture. |
|
|
|
Önemli Uyarılar |
: |
Two components must be mixed well. The mixture should be prepared enough as small parts. The mixing ratio should be considered for paint wastage. The ambient temperature should be between 5 – 35 ° C at the time of application Application tools must be cleaned with Merepoks Epoxy Thinner, after the application,. Paint doesn’t empty into drains. Application procedures defined above should be strictly observed. |
|
|
|
Danger Warning |
: |
R 20/21/22 : Harmful by inhalation, in contact with skin and if swallowed. :
|
|
|
|
Emergency Warning |
: |
S 2 : Keep out of the reach of children. : S 3 / 7 / 9 : Keep container tightly closed in a cool, well ventilated place. : S 24 / 25 : Avoid contact with skin and eyes. : S 29 : Do not empty into drains. : S 46 : If swallowed, seek medical advice immediately and show container or label. : S 51 : Use only in well ventilated areas. :
|